ASTM F1001 Chemical Test Battery* | |||||||
---|---|---|---|---|---|---|---|
Chemical | Zytron® | ChemTape® | |||||
100XP | 200 | 300 | 300 FR | 400 | 500 | ||
Acetone | NT | 17 | >480 | >480 | >480 | >480 | >480 |
Acetonitrile | NT | 52 | 87 | 87 | >480 | >480 | >480 |
Carbon Disulfide | NT | 2 | >480 | >480 | >480 | >480 | >480 |
Dichloromethane | NT | 2 | 70 | 70 | 88 | >480 | >480 |
Diethylamine | NT | 21 | >480 | >480 | >480 | >480 | 160 |
Dimethylformamide | NT | 77 | >480 | >480 | >480 | >480 | >480 |
Ethyl Acetate | NT | 14 | >480 | >480 | >480 | >480 | >480 |
n-Hexane | NT | 7 | >480 | >480 | >480 | >480 | >480 |
Methyl Alcohol | NT | >480 | 55 | 55 | >480 | >480 | >480 |
Nitrobenzene | NT | 97 | >480 | >480 | >480 | >480 | >480 |
Sodium Hydroxide | >480 | >480 | >480 | >480 | >480 | >480 | >480 |
Sulfuric Acid | >480 | >480 | >480 | >480 | >480 | >480 | >480 |
Tetrachloroethylene | NT | 21 | >480 | >480 | >480 | >480 | >480 |
Tetrahydrofuran | NT | 3 | >480 | >480 | >480 | >480 | >480 |
Toluene | NT | 6 | >480 | >480 | >480 | >480 | >480 |
*Normalized breakthrough times in minutes in accordance with ASTM F 739. |
Gases | |||||||
---|---|---|---|---|---|---|---|
Gases | Zytron® | ChemTape® | |||||
100XP | 200 | 300 | 300 FR | 400 | 500 | ||
Ammonia Gas | NT | NT | 39 | 39 | NT | >480 | NT |
1,3 Butadiene | NT | NT | >480 | >480 | NT | >480 | NT |
Chlorine Gas | NT | NT | >480 | >480 | NT | >480 | NT |
Ethylene Oxide Gas | NT | NT | 81 | 81 | 305 | >480 | NT |
Hydrogen Chloride Gas | NT | NT | >480 | >480 | NT | >480 | NT |
Methyl Chloride Gas | NT | NT | >480 | >480 | NT | >480 | NT |
Chemical Warfare Agent Data | ||
---|---|---|
Chemical Agent | Zytron® 300 | |
Breakthrough Time | Breakthrough Criteria | |
Agent testing was conducted at Battelle Labs in accordance with MIL-STD-282 and/or NFPA 1994-2001 Edition Standard on Protective Ensembles for Chemical / Biological Terrorism Incidents. | ||
Bis (2-chloroethyl) sulfide (Mustard:HD) | >480 MINUTES | 4.0 ug/cm2 |
Isopropyl methylfluorophosphonate (Sarin:GB) | >480 MINUTES | 1.25 ug/cm2 |
Chlorovinyl arsinedichloride (Lewisite:L) | >240 MINUTES | 4.0 ug/cm2 |
0-ethyl S-(2-diisopropylaminoethyl) methylphosphonothiolate (Nerve:VX) | >480 MINUTES | 1.25 ug/cm2 |
If you need to document a Kappler fabric against a specific chemical hazard not already in our database, we make it easy with a custom testing program. We’ll conduct third-party testing on your chemical, and if the fabric meets your requirements you agree to purchase a standard minimum number of garments. For details contact Customer Service at 1-800-600-4019 or email us at customerservice@kappler.com.
An selection tool that provides the data to help you make informed decisions about protective apparel.
Find Out MoreSources for all chemical test data are independent laboratories. All tests were performed under laboratory conditions and not under actual use conditions. Tests were performed on material samples, not actual garments. All chemicals tested at >95% concentration and 75° F, unless otherwise specified.
Kappler garments are made with American pride in Alabama where the accent is always on quality.